Category
Sf6 Full Closed Substation C Manual Mechanism Load Break Switch (LBS) Breaker
Overview Product Description 1.Product descriptionGas insulated ring main unit is for the secondary distribution network
Basic Info
Model NO. | SF6 full closed substation C manual mechanism |
Signal | Sf6 Insulated |
Function | Automatic Control, Protection, Monitoring, Measurement |
Certification | RoHS, CCC, ISO: 9001, CE |
Condition | New |
Customized | Customized |
Material | Stainless Steel |
Rated Voltage | 12kv 24kv 40.5kv |
Rated Current | 630A |
Switch | Sf6 Load Break Switch |
Operation | Motor/Manual Mechanism |
Protecting Type | Earthing ,Fuse,Microcomputer(for 35kv) |
Transport Package | Pallet Wooden |
Specification | 600x900x2000 |
Trademark | MINGZHE |
Origin | China |
HS Code | 8537209000 |
Production Capacity | 2000PCS/Week |
Product Description
1.Product descriptionGas insulated ring main unit is for the secondary distribution network 11/17.5/24/36 kV. It is a completely sealed system with a stainless steel tank containing all live parts and switching functions. A sealed steel tank with constant atmospheric conditions ensures a high level of reliability as well as personnel safety and a virtually maintenance-free system.
It offers a choice of either switch-fuse combination or circuit-breaker with relay for protection of the transformer. SafeRing can be supplied with an integrated remote control and monitoring unit.2.Service environment:a) Air temperature:Maximum temperature: +40ºC; Minimum temperature:-25ºCb) Humidity:Monthly average humidity 95%; Daily average humidity 90% .c) Altitude above sea level:Maximum installation altitude: 2500md) Ambient air not apparently polluted by corrosive and flammable gas, vapor etc.e) No frequent violent shakef)SF6 pressure:1.4barg) Gas leakage year rate:0.2‰/yearh)Ip range:IP67i)Thickness of gas stainless steel tank is 3.00mmj)Bus is 400mm2 Cu,Bus earthing is150mm2Cu3. Modularization designThe modular design scheme is adopted. The basic modules are load switch module, combined electrical module and other special function modules.Any combination of these modules forms a common box structure, in which any one function is roughly the same as the internal structure of the basic module4.Standards
IEC 62271-100 high voltage alternating current circuit breakersIEC 62271-105: alternating current switch-fuse CombinationIEC 62271-102: alternating current disconnectors and earthing switchesIEC 62271-200 A.C. metal enclosed switchgear and controlgear for rated voltage above 1 kV and up to and including 52 kVIEC 62271-103 high voltage switches for rated voltage above 1 kV and less than 52 kVIEC 60694: Common specifications for high-voltage switchgear and controlgear standards5. Flexible exit and extension modeAll modules can realize the connection mode of side outgoing line and side expanding line or outgoing line and top expanding line according to the customer's requirements, so as to meet the demand of power supply scheme to the greatest extentProduct Parameters
6.The main technical date
Item | Unit | Switch | Switch-fuse | Vacuum circuit-breaker |
Rated voltage | kV | 24 | 24 | 24 |
Power frequency withstand voltage | kV | 50 | 50 | 50 |
Impulse withstand voltage | kV | 125 | 125 | 125 |
Rated current | A | 630 | 2001) | 200 |
Breaking capacities: | ||||
active load | A | 630 | ||
closed loop | A | 670 | ||
off load cable charging | A | 141 | ||
off load transformer | A | 20 | ||
earth fault | A | 160 | ||
earth fault cable charging | A | 91 | ||
short-circuit breaking current | kA | see 2) | 16 | |
Making capacity | kA | 40 | see 2) | 40 |
Short time current 0,5 sec | kA | 16 | ||
Short time current 1 sec | kA | 16 | ||
Short time current 3 sec | kA | 16 |
1) Depending on the current rating of the fuse-link
2) Limited by high voltage fuse-links
SF6 Full metal closed ring main unit swich and mechanism
NO. | Name | Description |
1 | Circuit Break+Isolator switch | Three positions |
2 | Circuit Break+Isolator switch | Two positions |
3 | SF6 gas insulated substation earthing switch | |
4 | SF6 gas insulated substation load break | Three positions |
5 | SF6 gas insulated substation load break, | Two positions |
6 | Spring Mechanism | Substation C manual mechanism |
7 | Spring Mechanism | Substation C electric mechanism |
8 | Spring Mechanism | Substation C electric mechanism(with secend wires) |
9 | Spring Mechanism | Substation F manual mechanism |
10 | Spring Mechanism | Substation F electric open mechanism |
11 | Spring Mechanism | Substation F electric mechanism |
12 | Spring Mechanism | Substation F electric mechanism(with secend wires) |
13 | Spring Mechanism | Substation V manual mechanism with isolator |
14 | Spring Mechanism | Substation V electric mechanism with isolator |
15 | Spring Mechanism | Substation V electric mechanism with isolator(with secend wire) |
Our Advantages