Sf6 Full Closed Switchgear Substation C Electric Mechanism (with secend wires) Load Break Switch (LBS) Breaker

Sf6 Full Closed Switchgear Substation C Electric Mechanism (with secend wires) Load Break Switch (LBS) Breaker

Overview Product Description 1.Product descriptionGas insulated ring main unit is for the secondary distribution network
Basic Info
Model NO. switchgear Substation C electric mechanism(with se
Signal Sf6 Insulated
Function Automatic Control, Protection, Monitoring, Measurement
Certification RoHS, CCC, ISO: 9001, CE
Condition New
Customized Customized
Material Stainless Steel
Rated Voltage 12kv 24kv 40.5kv
Rated Current 630A
Switch Sf6 Load Break Switch
Operation Motor/Manual Mechanism
Protecting Type Earthing ,Fuse,Microcomputer(for 35kv)
Transport Package Pallet Wooden
Specification 600x900x2000
Trademark MINGZHE
Origin China
HS Code 8537209000
Production Capacity 2000PCS/Week
Product Description

1.Product descriptionGas insulated ring main unit is for the secondary distribution network 11/17.5/24/36 kV. It is a completely sealed system with a stainless steel tank containing all live parts and switching functions. A sealed steel tank with constant atmospheric conditions ensures a high level of reliability as well as personnel safety and a virtually maintenance-free system.

It offers a choice of either switch-fuse combination or circuit-breaker with relay for protection of the transformer. SafeRing can be supplied with an integrated remote control and monitoring unit.2.Service environment:a) Air temperature:Maximum temperature: +40ºC; Minimum temperature:-25ºCb) Humidity:Monthly average humidity 95%; Daily average humidity 90% .c) Altitude above sea level:Maximum installation altitude: 2500md) Ambient air not apparently polluted by corrosive and flammable gas, vapor etc.e) No frequent violent shakef)SF6 pressure:1.4barg) Gas leakage year rate:0.2‰/yearh)Ip range:IP67i)Thickness of gas stainless steel tank is 3.00mmj)Bus is 400mm2 Cu,Bus earthing is150mm2Cu3. Modularization designThe modular design scheme is adopted. The basic modules are load switch module, combined electrical module and other special function modules.Any combination of these modules forms a common box structure, in which any one function is roughly the same as the internal structure of the basic module

4.Standards

IEC 62271-100 high voltage alternating current circuit breakersIEC 62271-105: alternating current switch-fuse CombinationIEC 62271-102: alternating current disconnectors and earthing switchesIEC 62271-200 A.C. metal enclosed switchgear and controlgear for rated voltage above 1 kV and up to and including 52 kVIEC 62271-103 high voltage switches for rated voltage above 1 kV and less than 52 kVIEC 60694: Common specifications for high-voltage switchgear and controlgear standards5. Flexible exit and extension modeAll modules can realize the connection mode of side outgoing line and side expanding line or outgoing line and top expanding line according to the customer's requirements, so as to meet the demand of power supply scheme to the greatest extent
Product Parameters

6.The main technical date

ItemUnitSwitchSwitch-fuseVacuum circuit-breaker
Rated voltage kV242424
Power frequency withstand voltagekV505050
Impulse withstand voltage kV125125125
Rated current A6302001)200
Breaking capacities:
active load A630
closed loop A670
off load cable charging A141
off load transformer A 20
earth fault A160
earth fault cable charging A91
short-circuit breaking current kA see 2)16
Making capacity kA40see 2)40
Short time current 0,5 seckA 16
Short time current 1 seckA 16
Short time current 3 seckA16

1) Depending on the current rating of the fuse-link
2) Limited by high voltage fuse-links

SF6 Full metal closed ring main unit swich and mechanism

NO.NameDescription
1Circuit Break+Isolator switchThree positions
2Circuit Break+Isolator switchTwo positions
3SF6 gas insulated substation earthing switch
4SF6 gas insulated substation load breakThree positions
5SF6 gas insulated substation load break,Two positions
6Spring MechanismSubstation C manual mechanism
7Spring MechanismSubstation C electric mechanism
8Spring MechanismSubstation C electric mechanism(with secend wires)
9Spring MechanismSubstation F manual mechanism
10Spring MechanismSubstation F electric open mechanism
11Spring MechanismSubstation F electric mechanism
12Spring MechanismSubstation F electric mechanism(with secend wires)
13Spring MechanismSubstation V manual mechanism with isolator
14Spring MechanismSubstation V electric mechanism with isolator
15Spring MechanismSubstation V electric mechanism with isolator(with secend wire)


Sf6 Full Closed Switchgear Substation C Electric Mechanism (with secend wires) Load Break Switch (LBS) Breaker