Basic Info
Model NO. | Dz20 |
Poles Number | 3 |
Type | Circuit Breaker |
Function | Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection) |
Certification | ISO9001-2000, CE, CB |
Key Word | MCCB |
Key Word2 | Moulded Case Circuit Breaker |
Key Word3 | Circuit Breaker |
Rated Voltage | 380/400V AC |
Rated Frequency | 50Hz |
Breaking Capacity1 | 100ka |
OEM | Available |
Material | PC |
Rated Current | 630A |
Rated Insulation Voltage | 660V |
Transport Package | Standard Exporting Carton |
Trademark | SINGI |
Origin | Zhejiang, China |
Product Description
Product Introduction DZ20 series moulded case circuit breakers are suitable for AC 50hz, rated current from 16A to 630A, rated insulation voltage 660V, rated working voltage AC380V/400V and below circuits, this series of circuit breakers are generally used for power distribution, and can also be used to protect motors use. Under normal circumstances, the circuit breaker can be used for the infrequent switching of the line and the infrequent starting of the motor respectively.Circuit breakers for distribution are used to distribute electrical energy in the distribution network and serve as overload, short-circuit and under-voltage protection for lines and power equipment.The circuit breaker for protecting the motor is used in the power distribution network for the starting and running of the squirrel-cage motor, and for the overload, short-circuit and under-voltage protection of the squirrel-cage motor.
Constructure Feature
This series of circuit breakers is based on Y-type products and consists of four parts: insulating shell, operating mechanism, contact system and release. The operating mechanism of the circuit breaker has the function of quickly closing and breaking the contacts, and its 'close', 'open' and 'free trip' positions are distinguished by the handle position.C-type and J-type circuit breakers are derived and designed on the basis of Y-type circuit breakers. The J-type circuit breaker is a structural improvement of the contacts of the Y-type circuit breaker, so that in the case of a short circuit, the contacts can be quickly disconnected before the action of the mechanism to achieve the purpose of improving the on-off capability.Technica Parameter
Frame rating rated current Inm(A) | Conventional thermal current Ith(A) | Short circuit breaking capacity level | Short circuit breaking capacity kA | Circuit breaker rated current (A) |
Icu/cosf | Icu/cosf |
160 | 160 | C | 12/0.3 | / | 16.20.25.32.40.50.63.80.100.125.160 |
100 | 100 | Y | 18/0.3 | 14/0.3 | 16.20.25.32.40.50.63.80.100 |
J | 35/0.25 | 18/0.3 |
G | 100/0.2 | 50/0.25 |
250 | 250 | C | 15/0.3 | / | 100.125.160.180.200.225.250 |
225 | 225 | Y | 25/0.25 | 19/0.3 | 100.125.160.180.200.225 |
J | 42/0.25 | 25/0.25 |
G | 100/0.2 | 50/0.25 |
400 | 400 | C | 20/0.3 | / | 250.315.350.400 |
Y | 30/0.25 | 23/0.25 |
J | 42/0.25 | 25/0.25 |
G | 100/0.2 | 50/0.25 |
630 | 630 | C | 20/0.3 | / | 400.500.630 |
Y | 30/0.25 | 23/0.25 |
J | 50/0.25 | 25/0.25 |
1250 | 1250 | Y | 50/0.25 | 38/0.25 | 630.700.800.1000.1250 |
J | 65/0.2 | 32.5/0.25 |
2000 | 2000 | J | 100/0.2 | 50/0.25 | 1000.1250.1600.1800.2000 |
Test current name | Setting current multiple | Appointment time (h) | starting state |
ln≤63 | ln>63 |
Conventional non-tripping current | 1.05ln | ≥1 | ≥2 | cold start |
Conventional tripping current | 1.3ln | <1 | <2 | hot start |
Test current name | Setting current multiple | Appointment time (h) | starting state |
|
Conventional tripping current | 1.0ln | ≥2 | cold start |
Conventional tripping current | 1.2ln | <2 | hot start |