banner
Home / Products / Rcbo
Products
Good Future 6ka Type a/AC 1p+N Residual Current Operated Circuit Breaker 30, 100, 300mA RCBO

Good Future 6ka Type a/AC 1p+N Residual Current Operated Circuit Breaker 30, 100, 300mA RCBO

Package size per unit product 10.00cm * 10.00cm * 10.00cm Gross weight per unit product 0.500kg
Basic Info
Model NO. GFL2-40-1
Breaking Capacity Low Voltage Circuit Breakers
Operation Electric Type
Speed High-Speed Circuit Breaker
Arc-extinguishing Medium Air
Installation DIN Rail Mount
Structure RCBO
Poles Number 1
Type Circuit Breaker
Function Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB, RCBO
Certification ISO9001-2000, CE, Intertek Semko, CE, Ukca
Residual Current Sensitivity Universal.
Mode Electromagnetic
Curve Type AC, a
Rated Current in 6,10,16,20,25,32,40A
Poles 1p+N
Rated Voltage Ue 230/240V~
Insulation Voltage Ui 500V
Rated Frequency 50/60Hz
Rated Residual Operating Current 30, 100, 300mA
Rated Breaking Capacity 6, 000A
Electrical Life 4, 000 Cycles
Mechanical Life 10, 000 Cycles
Protection Degree IP20
Mounting on DIN Rail En60715(35mm)
Connection Powers Supply in Both Directions
Transport Package Customized Package and Express,Sea or Air Shipment
Specification GFL2-40 6kA Electromagnetic type A RCBO magnetic c
Trademark Good Future
Origin China
HS Code 8536200000
Production Capacity 3700000PCS /Year
Packaging & Delivery
Package size per unit product 10.00cm * 10.00cm * 10.00cm Gross weight per unit product 0.500kg
Product Description
featuresModeElectromagnetic
TypeAC, A
Rated current In6,10,16,20,25,32,40A
Poles1P+N
Rated voltage Ue230/240V~
Insulation voltage Ui500V
Rated frequency50/60Hz
Rated residual operating current(I△n)30,100,300mA
Break time under I△n≤0.1s
Rated breaking capacity6,000A
Energy limiting class3
Rated impulse withstands voltage (1.5/50) Uimp4,000V
Dielectric test voltage at ind.Freq. for 1min2kV
Pollution degree2
Thermo-magnetic release characteristicB, C
Mechanical FeaturesElectrical life4,000 Cycles
Mechanical life10,000 Cycles
Contact position indicatorYes
Protection degreeIP20
Reference temperature for setting of thermal element30ºC
Ambient temperature (with daily average≤35ºC)-5ºC~+40ºC
Storage temperature-25ºC~+70ºC
Installation Terminal connection typeCable/Pin-type busbar/U-type busbar
Terminal size top/bottom for cable25mm2 18-3AWG
Terminal size top/bottom for busbar25mm2 18-3AWG
Tightening torque2.5Nm 22In-lbs
MountingOn DIN rail EN60715(35mm) by means of fast clip device
ConnectionPower supply in both directions
Tripping Current Range TypeTripping current, I△/A
AC0.5I△n
ALagging AngleI△n>0.01AI△n≤0.01A
0.35I△n≤I△≤1.4I△n0.35I△n≤I△≤2I△n
90°0.25I△n≤I△≤1.4I△n0.25I△n≤I△≤1.4I△n
135°0.11I△n≤I△≤1.4I△n0.11I△n≤I△≤2I△n

Good Future 6ka Type a/AC 1p+N Residual Current Operated Circuit Breaker 30, 100, 300mA RCBO

Good Future 6ka Type a/AC 1p+N Residual Current Operated Circuit Breaker 30, 100, 300mA RCBO

Good Future 6ka Type a/AC 1p+N Residual Current Operated Circuit Breaker 30, 100, 300mA RCBO

Good Future 6ka Type a/AC 1p+N Residual Current Operated Circuit Breaker 30, 100, 300mA RCBO

Good Future 6ka Type a/AC 1p+N Residual Current Operated Circuit Breaker 30, 100, 300mA RCBO