Low Voltage Circuit Breakers Singi Breaker Electronic Electrical 2p DC OEM Dz47-63
Basic Info
Model NO. | DZ47-63 |
Breaking Capacity | Low Voltage Circuit Breakers |
Operation | Electric Type |
Speed | High-Speed Circuit Breaker |
Arc-extinguishing Medium | Air |
Installation | DIN Rail Mounting |
Structure | MCB |
Poles Number | 2 |
Type | Mini, Lighting "C"or Motor"D" |
Function | Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection) |
Certification | ISO9001-2000, CE, CB, CCC |
Keyword1 | MCB |
Keyword2 | Circuit Breaker |
Keyword3 | Miniature Circuit Breaker |
Keyword4 | Current Circuit Breaker |
Protection | Overload and Short Circuit |
Rated Current | 20AMP |
Standard | IEC60898 |
Pole | 2 |
Rated Voltage | 220/380VAC |
Case Material | PA66 |
OEM | Avaiable |
Keyword | Overload Protection |
Transport Package | Miniature Circuit Breaker MCB Pdf Viewer Standard |
Trademark | SINGI |
Origin | Zhejiang, China |
Production Capacity | 50000 Piece/Pieces Per Day |
Product Description
Key Words: MCB; Miniature circuit breakers
Key Parameters:
· CE/CB/ISO9001/CCC certificates;
· Rated voltage:230/400VAC;
· frequency50/60Hz;
· Rated current:6,10,16,20,25,32,40,50,63A;
· 1/2/3/4poles optional;
· Mechniacal life:10,000times;
· Flame-redardant:PA66 nylon material;
· Protection degree:IP20;
· With over load/short circuit protection;
· Standard:IEC60898;GB10963.1
· Enduring tem.55°C
· Breaking Capacity:4/6KA;
· Lighting/Motor protection optional
Application:
DZ47-63 high breaking miniature circuit breaker has the features of structure advanced, performance reliable, breaking capacity high, appearance elegant and its shell and parts are made of material with impact resistance, strong flame-retardant feature.
It is suitable to power system of 50or 60 frequency ,Ue 400V and below, Ui 63A and below.
It is mainly applied at office building, residence, for lighting , power distribution and overload and short circuit protection of equipment. Normally, it also can be used as the not frequent transfer of power system. It conforms to the standards IEC60898and GB10963.1.
Technical Parameters:
Rated voltage(V) | Poles | Rated current(A) | Rated short circuit breaking capacity | |
Test breaking capacity(KA) | Power factor | |||
230 | 1 | 6,10,16,20, 25,32,40 | 6 | 0.65~0.70 |
400 | 2,3,4 | 6 | ||
230 | 1,2 | 50,63 | 4 | 0.75~0.80 |
400 | 2,3,4 | 4 |
Remark:
1.mechanical life:10,000 times(off-on).
2.heat resistance: category 2 (temperature 55°C,relative humidity 95%).
3.wiring is terminal with clamp, cable dia.:25mm2.
Current Release Character Diagram:
Test current (A) | Rated current (A) | Requested time | Result | Start station | Remark |
1.13In | all | t>=1h | Don't trip | Cool | |
1.45In | All | T<1h | trip | heat | Current ascends the requested value stably in 5s |
2.55In | In<=32A | 1s<t<60s | trip | Cool | Auxiliary switch closed, power is on |
2.55In | In>32A | 1s<t<120s | trip | Cool | Auxiliary switch closed, power is on |
5In(Cmode) | All | t>=0.1s | Don't trip | Cool | Auxiliary switch closed, power is on |
10In(Cmode) | All | T<0.1s | trip | Cool | Auxiliary switch closed, power is on |
10(Dmode) | All | t>=0.1s | Don't trip | Cool | Auxiliary switch closed, power is on |
14In(Dmode) | All | T<0.1s | trip | Cool | Auxiliary switch closed, power is on |