Low Voltage Circuit Breakers Singi Breaker Electronic Electrical 2p DC OEM Dz47-63

Low Voltage Circuit Breakers Singi Breaker Electronic Electrical 2p DC OEM Dz47-63

Key Words: MCB; Miniature circuit breakers Key Parameters: · CE/CB/ISO9001/CCC certificates; · Rated voltage:230/400VAC;
Basic Info
Model NO. DZ47-63
Breaking Capacity Low Voltage Circuit Breakers
Operation Electric Type
Speed High-Speed Circuit Breaker
Arc-extinguishing Medium Air
Installation DIN Rail Mounting
Structure MCB
Poles Number 2
Type Mini, Lighting "C"or Motor"D"
Function Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification ISO9001-2000, CE, CB, CCC
Keyword1 MCB
Keyword2 Circuit Breaker
Keyword3 Miniature Circuit Breaker
Keyword4 Current Circuit Breaker
Protection Overload and Short Circuit
Rated Current 20AMP
Standard IEC60898
Pole 2
Rated Voltage 220/380VAC
Case Material PA66
OEM Avaiable
Keyword Overload Protection
Transport Package Miniature Circuit Breaker MCB Pdf Viewer Standard
Trademark SINGI
Origin Zhejiang, China
Production Capacity 50000 Piece/Pieces Per Day
Product Description

Key Words: MCB; Miniature circuit breakers

Key Parameters:
· CE/CB/ISO9001/CCC certificates;
· Rated voltage:230/400VAC;
· frequency50/60Hz;
· Rated current:6,10,16,20,25,32,40,50,63A;
· 1/2/3/4poles optional;
· Mechniacal life:10,000times;
· Flame-redardant:PA66 nylon material;
· Protection degree:IP20;
· With over load/short circuit protection;
· Standard:IEC60898;GB10963.1
· Enduring tem.55°C
· Breaking Capacity:4/6KA;
· Lighting/Motor protection optional

Application:
DZ47-63 high breaking miniature circuit breaker has the features of structure advanced, performance reliable, breaking capacity high, appearance elegant and its shell and parts are made of material with impact resistance, strong flame-retardant feature.
It is suitable to power system of 50or 60 frequency ,Ue 400V and below, Ui 63A and below.
It is mainly applied at office building, residence, for lighting , power distribution and overload and short circuit protection of equipment. Normally, it also can be used as the not frequent transfer of power system. It conforms to the standards IEC60898and GB10963.1.

Technical Parameters:

Rated voltage(V)PolesRated current(A)Rated short circuit breaking capacity
Test breaking capacity(KA)Power factor
23016,10,16,20,
25,32,40
60.65~0.70
4002,3,46
2301,250,6340.75~0.80
4002,3,44

Remark:
1.mechanical life:10,000 times(off-on).
2.heat resistance: category 2 (temperature 55°C,relative humidity 95%).
3.wiring is terminal with clamp, cable dia.:25mm2.

Current Release Character Diagram:
Test current
(A)
Rated current
(A)
Requested timeResultStart stationRemark
1.13Inallt>=1hDon't tripCool
1.45InAllT<1htripheatCurrent ascends the requested value stably in 5s
2.55InIn<=32A1s<t<60stripCoolAuxiliary switch closed, power is on
2.55InIn>32A1s<t<120stripCoolAuxiliary switch closed, power is on
5In(Cmode)Allt>=0.1sDon't tripCoolAuxiliary switch closed, power is on
10In(Cmode)AllT<0.1s tripCoolAuxiliary switch closed, power is on
10(Dmode)Allt>=0.1s Don't tripCoolAuxiliary switch closed, power is on
14In(Dmode)AllT<0.1stripCoolAuxiliary switch closed, power is on

Low Voltage Circuit Breakers Singi Breaker Electronic Electrical 2p DC OEM Dz47-63

Low Voltage Circuit Breakers Singi Breaker Electronic Electrical 2p DC OEM Dz47-63

Low Voltage Circuit Breakers Singi Breaker Electronic Electrical 2p DC OEM Dz47-63

Low Voltage Circuit Breakers Singi Breaker Electronic Electrical 2p DC OEM Dz47-63

Low Voltage Circuit Breakers Singi Breaker Electronic Electrical 2p DC OEM Dz47-63

rcuit breaker switch